Rendered at 12:54:05 07/28/25
Full-size item image
Primary image for MOX4 MOX-4 Oxygen Gas Sensor Medical Equipment White ABS AA829-M20 Oxygen Batter
Envío gratis

MOX4 MOX-4 Oxygen Gas Sensor Medical Equipment White ABS AA829-M20 Oxygen Batter

$2,030.88 MXN
Los buques de China Cn

Las opciones de envío

Los buques de 2 business days Detalles
$167.68 a Mexico
Los buques de China Cn

Política de oferta

OBO - El vendedor acepta ofertas en este artículo. Detalles

La política de devoluciones

Replacement product available within 90 days

Protección de compra

Opciones de pago

PayPal accepted
PayPal Credit accepted
Venmo accepted
PayPal, MasterCard, Visa, Discover, and American Express accepted
Maestro accepted
Amazon Pay accepted
Nuvei accepted

Las opciones de envío

Los buques de 2 business days Detalles
$167.68 a Mexico
Los buques de China Cn

Política de oferta

OBO - El vendedor acepta ofertas en este artículo. Detalles

La política de devoluciones

Replacement product available within 90 days

Protección de compra

Opciones de pago

PayPal accepted
PayPal Credit accepted
Venmo accepted
PayPal, MasterCard, Visa, Discover, and American Express accepted
Maestro accepted
Amazon Pay accepted
Nuvei accepted

Rasgos del artículo

Categoría:

Oxygen Sensors

cantidad disponible:

106 En stock

Condition:

New

UPC:

768771551939

Brand:

MAXTEC

Detalles del anuncio

Las políticas del vendedor:

Ver las políticas del vendedor

Envío de descuento:

No ofrece el envío combinado

Publicado en venta:

Más de una semana

Artículo número:

1632895071

Descripción del Artículo

MOX-4 MOX4 AA829-M20 OxygenSensor Oxygen Battery For Medical Equipment Features: The purpose of this document is to present the performance specification of the MOX4 oxygen gas sensor. This document should be used in conjunction with the Operating Principles (OP04) and the Product Safety Datasheet (PSDS 4). The data provided in this document are valid at 20C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture. Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP04). Poisoning CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation. When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic. Intended Use These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not including xenon), critical care, neonatal incubators and general oxygen monitors Specifications: Operating Principle Partial pressure electrochemical Output 9 mV to 13 mV in 210 mBar O2 Measurement Range 0 mBar to 1500 mBar O2 Response Time (T90)* 15 s (air to 100% O2) Baseline Offset* 200 ?V Linearity Linear 0% to 100% O2