Rendered at 15:55:36 05/20/25
Full-size item image
Primary image for NEW EUCHNER CES-A-AEA-04B / CESAAEA04B UNICODE EVALUATION UNIT 072000
Item image 1
Item image 2
Item image 3

NEW EUCHNER CES-A-AEA-04B / CESAAEA04B UNICODE EVALUATION UNIT 072000

$11,674.85 MXN
Los buques de United States Us

Don't miss out on this item!

There is only 1 left in stock.

Las opciones de envío

Estimado para llegar por Wed, May 28th. Detalles
Calculado por UPS en MX.
Los buques de United States Us

Política de oferta

OBO - El vendedor acepta ofertas en este artículo. Detalles

La política de devoluciones

Full refund available within 30 days

Protección de compra

Opciones de pago

PayPal accepted
PayPal Credit accepted
Venmo accepted
PayPal, MasterCard, Visa, Discover, and American Express accepted
Maestro accepted
Amazon Pay accepted
Nuvei accepted

Las opciones de envío

Estimado para llegar por Wed, May 28th. Detalles
Calculado por UPS en MX.
Los buques de United States Us

Política de oferta

OBO - El vendedor acepta ofertas en este artículo. Detalles

La política de devoluciones

Full refund available within 30 days

Protección de compra

Opciones de pago

PayPal accepted
PayPal Credit accepted
Venmo accepted
PayPal, MasterCard, Visa, Discover, and American Express accepted
Maestro accepted
Amazon Pay accepted
Nuvei accepted

Rasgos del artículo

Categoría:

Safety Relays

cantidad disponible:

Sólo uno en stock, para muy pronto

Condition:

New

MPN:

CES-A-AEA-04B

Country/Region of Manufacture:

Germany

Type:

Safety Relay

Order No.:

072000

Brand:

EUCHNER

UPC:

Does not apply

Detalles del anuncio

Envío de descuento:

Pesos de envío de todos los elementos se suman para el ahorro.

Publicado en venta:

Más de una semana

Artículo número:

1042361068

Descripción del Artículo

NEW EUCHNER CES-A-AEA-04B / CESAAEA04B UNICODE EVALUATION UNIT 072000 4 read heads can be connected 2 safety contacts (relay contacts) 1 internal normally open contact per safety contact Start button and feedback loop can be connected Unicode evaluation unit Category 4/PL e according to EN ISO 13849-1 Mechanical values and environment Housing material Housing Plastic PA6.6 Weight Net 0,25 kg Ambient temperature At UB = 24V DC -20 ... 55 C Atmospheric humidity Not condensing max.80 % rH Degree of protection IP20 Mounting method Mounting rail 35mm according to DIN EN 60715 TH35 Mounting distance Sideways toward the neighboring device min.10 mm Number of read heads Max. 4 read heads can be connected. Ready delay 10 ... 12 s Reaction time After change in the actuation status, 2 active actuators max.290 ms Duration of operation start button (for Manual start operating mode) min.250 ms After change in the actuation status, 1 active actuator max.210 ms After change in the actuation status, 4 active actuators max.450 ms After change in the actuation status, 3 active actuators max.370 ms Response delay start button (for Manual start operating mode) 200 ... 300 ms Switching frequency max.0,25 Hz Dwell time min.3 s Connection Screw terminals Safety contacts 13/14, 23/24 Number of safety contacts 2 Relays with internally monitored contacts Mechanical life Operating cycles (relay) 10 x 106 Electrical connection ratings Operating voltage DC UB 21 ... 24 ... 27 V DC Regulated, residual ripple 5 % Current consumption (with relay energized) 150 mA Fusing External (operating voltage UB) 0,25 ... 8 A EMC protection requirements In acc. with EN 60947-5-3 Degree of contamination (external, according to EN 60947-1) 2 Connection cross-section (screw terminals) 0,25 ... 2,5 mm Current via feedback loop 5 ... 8 ... 10 mA permissible resistance in feedback loop max.600 ? Safety contacts 13/14, 23/24 Type of output Relay contacts, floating Switching current At switching voltage AC/DC 17 ... 30 V 15 ... 6000 mA At switching voltage AC/DC 1 ... 60 V 1 ... 300 mA At switching voltage AC 17 ... 230 V 15 ... 1500 mA Fusing External (safety circuit) according to EN 60269-1 6 AgG or 6 A circuit breaker (characteristic B or C) Utilization category acc. to EN 60947-5-1 AC-15 230 V 1.5 A DC-13 24 V 1.2 A AC-12 30 V 6 A 60 V 0.3 A DC-12 60 V 0.3 A 30 V 6 A Switching load According to c UL us Class 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A Rated insulation voltage Ui 250 V Rated impulse withstand voltage Uimp 4 kV Rated conditional short-circuit current 100 A Discrepancy time (Between the operating points of both relays, with 4 active actuators) max.400 ms STATE LED LED indicator Status LED LED OUT LED indicator Safety outputs status DIA LED LED indicator Diagnostics LED Monitoring outputs: Diagnostic DIA, door monitoring outputs O1,O2,O3,O4 Type of output Semiconductor output, p-switching, short circuit-proof Output voltage 0,8 x UB ... UB V DC Output current max.20 mA Inputs: Start button S, test input TST Input current HIGH 5 ... 8 ... 10 mA Input voltage LOW 0 ... 2 V DC HIGH 15 ... UB V DC Work area Repeat accuracy R According to EN 60947-5-2 max.10 % Other For the approval acc. to UL the following applies Reliability values according to EN ISO 13849-1 Monitoring of the safety guard position PFHD at = 0,1 A 1.3 x 10-8 PFHD at = 3 A 1.5 x 10-8 (description exceeds maximum possible length)